International electrotechnical commission this is a. Iec 60417 graphical symbols for use on equipment 5336 defibrillationp roof type cf applied part to identify a defibrillationproof type cf applied part complying with iec 606011. To provide instruction that the protective conductor pe should be connected first to main protective earthing terminal before connecting the line and neutral to avoid shock haz. To identify an earth ground terminal in cases where neither the symbol 5018 nor 5019 is explicitly stated. Annex a introduction of new symbols symbol symbol description. Each protective conductor connecting point shall be marked or labeled as such using the symbol iec 604175019 or with the letters pe, the graphical symbol being preferred, or by use of the bicolour combination greenandyellow, or by any combination of these. If there are unused symbol numbers, the space is left free. Jan 28, 2014 the other symbol with a circle number 5019 is for any other terminals that are bonding hazardous and accessible components to ground. In 2002 iec launched an online database format for the symbol library, available on subscription from the iec website. General requirements for basic safety and essential performance. This part of iec 60417 contains graphical symbols included in iec 604171 for reproduction purposes. It is complemented by an alphabetical index and a graphical survey of the symbols. Additional information is provided to the user by classifications to form and function, and the examples of application.
Iec 604175017 earth ground iec 604175841 defibrillationproof type b applied part iec 604175021 equipotentiality. Graphical symbol for use on washable shavers and wet shavers. Iec 60417 5017 earth ground iec 60417 5841 defibrillationproof type b applied part iec 60417 5021 equipotentiality. Contact iec sc 3c if a suitable symbol does not exist in the iec 60417 database. Iec 604175333 type bf to identify a type applied part bf applied part complying with iec 606011. To identify a type b applied part complying with iec 606011. International electrotechnical commission technical committee. Note 2 the original date of issue of each symbol is shown in table 1. Complete document graphical symbols for use on equipment part 2. Graphical symbol for use on washable shavers and wet.
Use these selfadhesive paper electrical symbol labelsonaroll to identify various electrical components and equipment standard electrical symbol size is 12, although also available in 34 electrical equipment and component labels are sold on rolls of 500. Iso 7010p026 2011 05 do not use this device in a bathtub, shower or waterfilled reservoir. View all the iso 7000 iec 60417 graphical symbols for use on equipment after our recent blog why the power symbol looks the way it does we went down the rabbit hole of looking for more symbols and stumbled upon this online catalog of all the graphic symbols from iso 7000 iec 60417 standards. View all the iso 7000 iec 60417 graphical symbols for use.
These international standards are maintained respectively by iectc 3, subcommittee sc 3c and isotc 145, subcommittee sc 3. Iec 60417 iso 7000joint iec 60417 and iso 7000 collection. The value of the potential may be indicated adjacent to the symbol published. To provide instruction that the protective conductor pe should be connected first to main protective earthing terminal before connecting the line and neutral to avoid shock hazard, and that a pe connection to the main pe terminal is essential before connecting the mains to avoid electric shock. Iso 7000 iec 60417 graphical symbols for use on equipment additional information. To identify an earth ground terminal in cases where neither the symbol 5018 nor 5019 is explicitly required. The value of the potential may be indicated adjacent to the symbol published in. This symbol is part of collections iso 7000 iec 60417 graphical symbols for use on equipment. The iec version of this standard is nearly identical to the european version, en 60204.
Iec 60417 6043 caution, sharp edges to indicate that the marked item contains sharp edges and should not be touched without taking care. View all the iso 7000 iec 60417 graphical symbols for. Standard symbol title of symbol description of symbol. To identify electrical appliances, for example wet shavers, which are suitable for use in a bath or shower. Clearly it would be useful to anyone writing technical or user manuals. After our recent blog why the power symbol looks the way it does we went down the rabbit hole of looking for more symbols and stumbled upon this online catalog of all the graphic symbols from iso 7000 iec 60417 standards from heavy machinery operating symbols to the numerous and varied laundry icons to the hairgrabbing what does that icon mean. Media in category iec 60417 symbols the following files are in this category, out of total. Iec 60417 graphical symbols for use on equipment iec 604175017 earth ground to identify an earth ground terminal in cases where neither the symbol 5018 nor 5019 is explicitly required. Iec 60417 graphical symbols are primarily intended to. Iec 60417 6173, connection, protective conductor pe. The type of alarm may be indicated inside the open triangle or below the triangle published in.
This file is licensed under the creative commons attributionshare alike 4. Iec 604171 and 604172 cancel and replace iec 60417 and all its supplements. These are iec 60417 symbols, so i would like to answer this from an iec reference frame. All structured data from the file and property namespaces is available under the creative commons cc0 license. Iec 60417 has the status of a horizontal standard in accordance with iec guide 108. Here are the precise iec definitions for each symbol. Test report iec 6033522 andor en 6033522 household. The actual symbols used to indicate ground terminals are found in iec 60417 graphical symbols for use on equipment figure 1. These international standards are maintained respectively by iec tc 3, subcommittee sc 3c and isotc 145, subcommittee sc 3. Jan 01, 2012 the actual symbols used to indicate ground terminals are found in iec 60417 graphical symbols for use on equipment figure 1. Files are available under licenses specified on their description page. Proposal to include iec power symbols terence eden joe loughry bruce nordman 14th february 2014 abstract the international symbol iec 604175009. Iso 7000 iec 60417 graphical symbols for use on equipment.
The following table lists the meaning of the safety symbols labeled on the equipment. Graphical symbol for use on washable shavers and wet shavers last update. Following this decision, in 2004 cenelec decided to cease publication of en 60417 in paper form, to withdraw the thenexisting standards and formally to adopt the iec database without any changes for use in europe. The type of alarm may be indicated inside the open triangle or below the triangle.
Electrical symbol labelsonaroll protective earth seton. Iec 604175019 shall be used in conjunction with this symbol. Iso 7000 provides a synopsis of those graphical symbols which are placed on equipment or parts of equipment of any kind in order to instruct the persons using the equipment as to its operation. When the above symbol is used on a product, it is used in a combination of symbols as given below. It supplies a snapshot of all the symbols in the iec database at the time of publication. Furthermore, for electronically published documentation, it is. Annex a introduction of new symbols symbol designation. International electrotechnical commission international. The other symbol with a circle number 5019 is for any other terminals that are bonding hazardous and accessible components to ground. Iec 60417 has the status of a horizontal standard in accordance with iec. Symbol designation symbol description iec 60417 6042 caution, risk of electric shock to identify equipment, for example, the welding power source, that has risk of electric shock.
Note 1 generally, three of the original drawings are shown on each page. Iso 7000 iec 60417 graphical symbols for use on equipment informacion adicional. Clarions symbolonly labels in this category are used to indicate functions and controls on equipment. Pd 60417 snapshot takes the form of a oneoff pdf download obtained with a single purchase. Furthermore, for electronically published documentation, it is crucial for this and a few other symbols to be defined because it makes them searchable in plain text. As iec 60417 is now implemented in a database at co, the proposal of withdrawal means that the symbol. In the application of this symbol, iec 604176042 and iec 604175019 shall be used in conjunction with this symbol. It therefore offers endusers a onestop shop for all such graphical symbols. Iec 60417 1 and 60417 2 cancel and replace iec 60417 and all its supplements. International electrotechnical commission iec page count. Withdrawal of symbol 5017 from iec 60417 tc16 strongly recommends that the symbol 5017 is withdrawn from the iec 60417, and that the use of this symbol for marking of products or for marking of product terminals is discontinued. For those engineers that build machinery, note that in november. Contains graphical symbols used to identify equipment or a part of equipment, indicate functional states, designate connections, provide information on packaging or provide instruction for the operation of the equipment.
202 453 868 217 1355 811 833 258 1424 1005 682 385 1425 333 1254 71 709 1098 1075 427 1065 235 990 1132 539 1103 177 319 931 357 666 1118 1388 768 877 1200 1202 305 1208 1221 825 221